Tulkot latviski

Benchtop multimeter | VFD x2 5 digit (50000) | True RMS | Plug: EU

EB Kods: EB189512172

Ražotāja preces kods: 
GDM-8342 USB

Ražotājs, zīmols: 
GW INSTEK

729,63 
Ar PVN / gb
Pieejams piegādātāja noliktavā 1 gab.
⛟ Piegāde 1-3 darba dienas pēc apmaksas. 
-+

Type of meterbenchtop multimeter
Measuring instrument featuresHOLD function
Measuring instrument featuresMIN/MAX function
Measuring instrument featuresoperates with thermocouple types: J, K, T
Measuring instrument featuresREL function
Measuring instrument featuresusb storage for storage and recall data
Kind of display usedVFD
DC voltage measuring range500mV
DC voltage measuring range5V
DC voltage measuring range50V
DC voltage measuring range500V
DC voltage measuring range1kV
DC voltage measuring accuracy±(0.02% + 4 digit)
AC voltage measuring range500mV
AC voltage measuring range5V
AC voltage measuring range50V
AC voltage measuring range500V
AC voltage measuring range750V
AC voltage measuring accuracy±(0.35%...3%)
AC current measuring range500µA
AC current measuring range5mA
AC current measuring range50mA
AC current measuring range0.5A
AC current measuring range5A
AC current measuring range10A
DC current measuring range0.5mA
DC current measuring range5mA
DC current measuring range50mA
DC current measuring range500mA
DC current measuring range5A
DC current measuring range10A
DC current measuring accuracy±(0.05% + 4 digit) @5mA
DC current measuring accuracy±(0.05% + 4 digit) @50mA
DC current measuring accuracy±(0.05% + 5 digit) @500µA
DC current measuring accuracy±(0.1% + 4 digit) @500mA
DC current measuring accuracy±(0.25% + 5 digit) @5A
DC current measuring accuracy±(0.25% + 5 digit) @10A
AC current measuring accuracy±(0.5% + 20 digit)@(5mA...500mA)
AC current measuring accuracy±(0.5% + 30 digit)@(5A...10A)
AC current measuring accuracy±(0.5% + 40 digit)@500µA
True effective value measurementTrue RMS
Resistance measuring range500Ω
Resistance measuring range5kΩ
Resistance measuring range50kΩ
Resistance measuring range500kΩ
Resistance measuring range5MΩ
Resistance measuring range50MΩ
Diode test0.83mA @5V
Continuity testacoustic indication
Standard equipmentcable GTL-207
Standard equipmentmains cable
Standard equipmenttest leads
MeasurementAC current
MeasurementAC voltage
Measurementcapacitance
MeasurementDC current
MeasurementDC voltage
Measurementfrequency
Measurementresistance
Measurementtemperature
InterfaceUSB
Plug variantEU
Related items5790D
Related items5793D
Related items5794D
Related items5795D
Related items5797D
Related itemsBKP60
Related itemsEX801515
Related itemsEX871515
Related itemsEX872502
Related itemsEX881602
Related itemsEX881603
Related itemsEX881605
Related itemsPKT-PTA
Related itemsPKT-PTF-10
Related itemsPKT-PTF-20
Related itemsPKT-PTF-25
Related itemsPKT-PTF-30
Related itemsPKT-PTF-40
Related itemsPKT-PTF-50
Related itemsPKT-PTF-55
Related itemsPKT-PTF-56
Related itemsPKT-PTF-60
Related itemsSE027
Related itemsSE028
Related itemsSE029
Related itemsSE030
Related itemsSE031
Related itemsSE046
Related itemsSE047
Related itemsSE048
Related itemsSE049
Related itemsSE050
Related itemsSE051
Related itemsSE052
Related itemsSE053
Related itemsSE054
Related itemsSE055
Related itemsSE056
Related itemsSE057
Related itemsSE058
Related itemsSE059
Related itemsSE060
Related itemsSE061
Related itemsSE062
Related itemsSE001
Related itemsSE002
Related itemsSE003
Related itemsSE004
Related itemsSE000
Related itemsTESTO-06020393
Related itemsTESTO-06020645
Related itemsTESTO-06024592
Related itemsTESTO-06024892
Related itemsTESTO-06280020
Related itemsTESTO-06280027
Related itemsTESTO-06281292
Related itemsTESTO-06287533
Related itemsTP200
Related itemsTP400
Related itemsTP870
Related itemsTP873
Related itemsTP873-5M
Related itemsTP882
Related itemsTP-111
Related itemsTP-112
Related itemsTP-02
Related itemsTP-03
Related itemsTP-04
Related itemsTP-06
Related itemsTP-08
Related itemsTP-09
Related itemsTPK-59
Related itemsTPK-62
Related itemsUTT10K
Related itemsUTT12
Temperature measuring range (with K-type thermocouple)-200...300°C
Temperature measuring range (with J-type thermocouple)-200...300°C
Temperature measuring range (with T-type thermocouple)-200...300°C
Display parameters5 digits (50000)
Softwareincluded